Skip to Content

BASIX Thermal Performance Methods NSW 2026: DIY vs NatHERS Simulation vs Passive House for New Homes

28 October 2026 by
BASIX Thermal Performance Methods NSW 2026: DIY vs NatHERS Simulation vs Passive House for New Homes

Answer first: BASIX gives new NSW homes three ways to pass thermal performance: the DIY method, the NatHERS Simulation method and the Passive House standard method. DIY is a web-based deemed-to-satisfy check for simpler single dwellings within strict limits, with no assessor needed. Simulation suits larger, bespoke or multi-dwelling designs. Passive House applies only where eligible and certified.

By: giantA Pty Ltd · Updated 29 October 2026

What are the three BASIX thermal performance methods?

The thermal performance section of BASIX limits how much heating and cooling a new home is expected to need. According to the NSW Planning Portal’s BASIX thermal performance help notes (last updated 19 October 2026), you must select one of three methods to complete it:

  • Do-It-Yourself (DIY) method — a simplified assessment for single dwelling houses that use common construction materials and methods.
  • Simulation method — a detailed assessment using Nationwide House Energy Rating Scheme (NatHERS) accredited software, able to model a wider range of materials, more complex designs and multi-dwelling developments such as townhouses and apartments.
  • Passive House standard method — for dwellings designed and built to the Passive House standard, with the design verified by a certified Passive House designer in the Passive House Planning Package (PHPP) software.

The Portal says DIY and Simulation are “broadly equivalent across a large sample of dwellings”, but outcomes are likely to differ for an individual house: DIY estimates heating and cooling loads from limited inputs, while Simulation calculates them in thermal simulation software. For a particular design, that can decide whether you pass easily, pass only with costly glazing, or fail. This guide covers choosing a method for a new home or granny flat; renovations work differently (see below).

How do the DIY, Simulation and Passive House methods compare?

Summary from the Planning Portal’s help notes (check current wording before you lodge):

FeatureDIY methodSimulation methodPassive House standard method
Who prepares itAnyone with a Planning Portal account entering data in the BASIX toolAn accredited NatHERS assessor using approved software; loads are entered into BASIXA certified Passive House designer (or Passive House certifier) using PHPP
Dwelling typesAny single dwelling — detached, attached or granny flat — within the DIY limitsSingle dwellings and multi-dwelling developments, including townhouses and apartmentsDescribed as available to single and multi-dwelling developments, but only in eligible locations
How compliance is shownMinimum insulation plus glazing and shading selections keep estimated loads under BASIX maximumsSimulated heating and cooling loads from the NatHERS certificate must be below the BASIX maximum loadsPHPP verification of space heating, space cooling and air tightness requirements
Key limits≤300 m² conditioned floor area, one or two storeys, glazing 10–40% of conditioned floor area, ≤40 windows and glazed doors, skylights ≤3 m², and moreSimulations must follow the BASIX Thermal Performance ProtocolLocation eligibility; blower door test after construction
Design flexibilityLow — limited shading types and fixed assumptionsHigh — wider range of materials, shading devices and insulationHigh, but to a demanding international standard
Extra documentsNone beyond the BASIX certificateNatHERS certificate and stamped plansPHPP report and written endorsement; blower door test results at occupation certificate stage

Sources: Planning Portal pages on the DIY method, the Simulation method (updated 15 October 2026) and the Passive House standard method (updated 9 March 2026).

Can my house use the BASIX DIY method?

The Portal describes the DIY method as “a web-based Deemed-to-Satisfy method” and says any single dwelling (detached, attached or granny flat) can be assessed with it — provided the design meets all of the following criteria:

  1. The conditioned floor area is not more than 300 m².
  2. The dwelling is single or double storey.
  3. There is no open mezzanine area exceeding 25 m².
  4. There is no third-level habitable attic room.
  5. The glazing area is between 10% and 40% of the conditioned floor area.
  6. There are no more than 40 windows and glazed doors (windows of the same orientation cannot be combined to get under the limit).
  7. The total area of skylights is not more than 3 m².

The tool checks floor area, storeys and mezzanine area against your site details, and some criteria become commitments on the certificate, so they must stay true through construction.

Does a garage underneath count as a storey?

Not necessarily. The DIY help notes say that if the ground floor has no conditioned floor area (as BASIX defines it), it is not counted as one of the storeys. The Portal’s DIY method FAQs give the example of a ground-level garage with two storeys of living areas and bedrooms above: it is still treated as two storeys and can use DIY.

What about alfresco areas and outdoor mezzanines?

The 25 m² limit applies to indoor open mezzanines. The FAQs say an outdoor mezzanine or alfresco area larger than 25 m² can still be assessed with DIY, because it is entered in the same way as a balcony.

What design features push a house out of DIY?

In our experience, architect-designed homes most often exceed the 40% glazing ceiling, the 40-window count or the 300 m² cap, or include large open mezzanines over double-height voids. DIY also offers only certain shading types, and overshadowing only counts if it is directly in front of the centre at the base of the glazing. If even one criterion cannot be met, the Portal says to use the Simulation method.

Why might a design pass NatHERS Simulation but fail DIY?

The DIY FAQs address this directly: house plans that score 6 to 7 NatHERS stars under Simulation can still fail BASIX under DIY. The Portal explains that DIY needs far fewer inputs to describe a house, and “in some cases, this reduced flexibility results in a higher level of stringency”. DIY is “not a full substitution for the Simulation method”.

Insulation is a big part of the gap. DIY sets minimum insulation by NCC climate zone, similar to the NCC deemed-to-satisfy elemental approach but lower (because of condensation and buildability concerns), and the only extra you can claim is an optional higher commitment:

  • external walls (other than cavity brick): an additional R1.0
  • suspended floors: an additional R0.5
  • ceiling and roof: an additional R1.0

Beyond that, DIY cannot credit a better-insulated envelope. For bespoke architectural designs and specific construction features, the Portal recommends the Simulation method.

Can I pick a dark roof under DIY?

Often not. The Portal’s page on the increase to BASIX standards says that, to align with the NCC 2022 deemed-to-satisfy elemental provisions, dark roofs (solar absorptance greater than 0.7) cannot be selected in DIY for developments in coastal areas north of Wollongong — including Greater Sydney — and inland areas west of the Great Dividing Range. Dark roofs can still be modelled under the Simulation or Passive House methods, although other specifications will usually need to improve to compensate.

How do you get a failing DIY assessment to pass?

The DIY FAQs set out a step-by-step approach. In summary:

  1. Check the glazing ratio (10–40% of conditioned floor area) via “List of things you must address” on the Status page.
  2. Commit to higher minimum insulation using the optional questions in the Construction Details section.
  3. Adjust glazing. For heating loads, favour north glass, reduce south glass and lower the U-value. For cooling loads, reduce east, west and north-west glass, add shading and lower the solar heat gain coefficient (SHGC).
  4. Change the design or switch to Simulation if the steps above still do not work.

Some measures pull in opposite directions — lower-SHGC glass reduces cooling load but can raise heating load. BASIX sets separate maximum heating and cooling loads by climate zone, and in some climate zones a maximum total load for certain building types, so strong performance in one does not offset a failure in the other.

Good passive design avoids this wall — see passive design before BASIX.

What do DIY window commitments mean on site?

According to the DIY FAQs:

  • For windows with single clear or double clear glass in aluminium or timber/uPVC/fibreglass frames, certifiers check compliance by visual inspection, so the certificate shows no U-value or SHGC. “Aluminium” here means simple frames, not thermally broken aluminium.
  • For all other window types, compliance is checked by comparing the installed windows’ U-value and SHGC against the acceptable range on the certificate’s window table. The frame and glass descriptions are for reference only.
  • Changing a window type later (for example, hinged to sliding) may need a revised certificate; for non-clear types, revise if no product meets the certified U-value and SHGC range.

Keep supplier performance data for the certifier — see our guide to the BASIX completion receipt.

How does the Simulation method work?

An accredited assessor models the dwelling in approved NatHERS software, and the heating and cooling loads from their certificate are entered into BASIX. They must be below the maximum loads BASIX sets for your climate zone (the Portal’s Energy standards and thermal loads calculator shows these).

The Portal says Simulation “allows for a wider selection of building materials, shading devices and insulation, which may reduce the need for improved glazing and other added building costs”. Points to know:

  • The BASIX Thermal Performance Protocol applies. The current version (7 June 2024) is for the current V4 BASIX standards. Where the protocol differs from the NatHERS Technical Note, the protocol prevails.
  • Only certain software is accepted. The Portal’s software tools note (June 2024) lists AccuRate, BERS Pro, FirstRate 5 and Hero; confirm current accreditation on nathers.gov.au.
  • Councils and certifiers verify the NatHERS certificate against the BASIX certificate and plans — see our simulation method checks guide.
  • Not usually for renovations. The Simulation method is not available for alterations and additions except in special circumstances.

Is a NatHERS star rating the same as passing BASIX thermal?

Not exactly. NatHERS’ new homes page (updated 3 September 2026) says an assessment produces a Star Rating (out of 10, for the building fabric) and a Whole of Home rating (0–100+, including fixed appliances and renewables), and that in NSW most BASIX assessments use the Star Rating as part of the assessment.

BASIX tests the simulated heating and cooling loads against its own caps, not the star band. The October 2023 increase lifted houses from an average of 5.5–6 stars to 7 stars, in line with NCC 2022 (except climate zones 9, 10 and 11 and apartment buildings up to 5 storeys). A 7-star design will often pass, but a separate heating or cooling cap can still fail it. For background, see our 7-star NatHERS and BASIX guide.

How do thermal loads affect the BASIX Energy score?

The thermal help notes say thermal loads are combined with the heating and cooling appliances selected in the Energy section to calculate that part of the Energy score. Lower loads improve the Energy score, which the Portal says can be an effective way to pass Energy in cold or hot climates.

When does the Passive House standard method make sense?

This method suits projects already committed to Passive House. A certified Passive House designer or certifier verifies the design in PHPP, and you enter the designer’s name in BASIX. The Portal sets these conditions:

  • Location eligibility — only certain NSW locations, where Passive House dwellings have been shown to perform at least as well as Simulation passes.
  • Documentation — a PHPP report showing space heating, space cooling and air tightness requirements are met, plus the designer’s written endorsement.
  • Air tightness testing — after construction, a blower door test by a tester registered with the Air Tightness Testing and Measurement Association must show no more than 0.6 air changes per hour at 50 Pa (ACH50). The results are attached to the BASIX certificate when applying for the occupation certificate.

One wording difference to flag: the thermal overview says this method applies only to single dwelling houses, while the dedicated Passive House page says single and multi-dwelling developments. For multi-dwelling housing, confirm with your Passive House designer or the BASIX help desk. More background: May tool upgrades and the Passive House method.

How should you choose a method for your project?

A practical decision sequence for new homes and granny flats:

  1. Confirm the assessment pathway. The Portal’s Starting a BASIX application page explains how your selections set the pathway (single dwelling, multi-dwelling or alterations and additions). A granny flat — new or a garage conversion — follows the single dwelling pathway. Once you start the application, the pathway cannot be changed.
  2. Screen against the DIY limits using your sketch design: conditioned floor area, storeys, mezzanine, glazing ratio, window count and skylights.
  3. Check roof colour and glazing ambitions. A dark roof in Greater Sydney, or a glass-heavy design, points to Simulation.
  4. Test DIY first for simple designs. Since the May 2026 upgrade, data is retained when switching between Simulation and DIY, so a quick DIY test costs little time.
  5. Engage a NatHERS assessor early for larger, bespoke, multi-dwelling or highly glazed designs, so simulation informs the design.
  6. Lock the specification into the drawings (DA and CC/CDC plans) and validate the certificate at lodgement — see BASIX certificate validation.

Since May 2026, new home certificates show the thermal performance method on the first page (see BASIX tool upgrades May 2026). If the design changes after issue, see BASIX certificate validity and revisions.

What about renovations and granny flats?

Alterations and additions: BASIX applies to renovations of $50,000 or more, and to pools and spas with a total volume greater than 40,000 litres, according to the Portal’s alterations and additions page. The thermal section for alterations asks whether walls and ceilings are new or altered construction; a closed-off new room under 15 m² with under 20 m² of total glass gets lower glazing and shading criteria. Simulation is only available for alterations in special circumstances (see our alterations simulation guide).

Granny flats: DIY expressly covers granny flats, though the glazing ratio and window count still apply. Where the lot includes common property or the project involves subdivision, the multi-dwelling pathway applies instead — see our BASIX dual occupancy guide and BASIX for granny flats.

Where does giantA fit in?

giantA screens designs against the DIY limits at concept stage, coordinates NatHERS assessors where Simulation is the better route, and carries BASIX commitments through to DA and CC drawings for new homes, granny flats and renovations across NSW. See BASIX and NatHERS, BASIX assessment in Sydney or our design and approvals services, or contact giantA for a project review.

Frequently asked questions

What is the BASIX DIY method?

A web-based deemed-to-satisfy method in the BASIX tool: you commit to minimum insulation and select glazing and shading so estimated loads stay within BASIX maximums. Only single dwellings meeting all DIY criteria can use it.

What is the floor area limit for BASIX DIY?

No more than 300 m² of conditioned floor area, alongside the other DIY limits on storeys, mezzanines, glazing ratio, window count and skylights.

Do I need a NatHERS assessor for BASIX?

Only for the Simulation method. Single dwellings meeting the DIY criteria can be completed without one, though results may differ.

Can I switch from DIY to Simulation?

Yes. Since May 2026, data is retained when switching methods. The assessment pathway, however, cannot be changed once the application starts.

Can I use DIY with a dark roof in Sydney?

No. Roofs with solar absorptance above 0.7 cannot be selected in DIY in Greater Sydney and the other listed areas. Use Simulation or Passive House instead.

Is Passive House accepted for BASIX everywhere in NSW?

No — only in eligible locations, with a PHPP report, designer endorsement and a blower door test of no more than 0.6 ACH50.

Preferred sources (verify current versions)

Class 2 Performance Solutions NSW 2026: Regulated Designs, Fire Engineering Reports, FRNSW Consultation and Who Declares What Under the DBP Act