Answer first: The BASIX Energy section scores a new NSW home on its hot water system, heating and cooling, ventilation fans, lighting, pools and spas, and any on-site solar PV. The score must meet the energy use standard for your climate zone and home type. Hot water is usually the biggest lever, and a fully electric home scores highest.
By: giantA Pty Ltd · Updated 19 November 2026
What does the BASIX Energy section actually measure?
BASIX (the Building Sustainability Index) has three main parts for a new dwelling: Water, Thermal Performance and Energy. According to the NSW Planning Portal’s Energy section guidance, the Energy section sets energy use standards to reduce the greenhouse gas emissions of new residential dwellings. It looks at the efficiency of the fixed appliances and equipment you nominate and at any alternative energy source, such as solar panels, installed on the site.
The Portal lists eight areas the section assesses:
- hot water systems
- heating and cooling
- ventilation
- lighting
- pools and spas
- alternative energy sources (for example photovoltaics)
- other energy uses (cooking, clothes drying, appliances)
- central systems (multi-dwelling developments only)
Every choice becomes a commitment on the BASIX certificate that must be shown on the plans and installed before the occupation certificate. In effect, the Energy section sets your equipment schedule.
If you are new to BASIX, start with our step-by-step BASIX certificate guide, then come back here for the energy detail.
How is the BASIX energy score calculated?
The Portal’s Assessment against requirements page explains that the BASIX Tool produces a water score and an energy score (higher is better), plus a heating load and cooling load for thermal performance (lower is better). The energy score is the estimated reduction in greenhouse gas emissions compared with a similar “benchmark” dwelling from before BASIX was introduced in 2004.
The benchmark is 3,292 kilograms of carbon dioxide per person per year, the average for pre-BASIX homes. If your home is estimated to produce, say, 50% fewer emissions than that benchmark, your energy score is 50.
To pass, the development must have an energy score that meets or exceeds the energy use standard. The standards sit in Table 1 of Schedule 1 of the State Environmental Planning Policy (Sustainable Buildings) 2022. They are expressed as a percentage reduction and vary with:
- the climate zone of the site, and
- the development type (houses, and low, medium and high rise apartment buildings).
To look up the exact target for your postcode and building type, the Department publishes an Energy standards and thermal loads calculator (Excel). We do not quote a single “Sydney target” here because the number depends on your location and dwelling type.
What changed with the higher standards from 1 October 2023?
The Portal’s Increase to BASIX Standards page sets out the changes that took effect on 1 October 2023. For the Energy section, the key points are:
| Change | What it means for your design |
|---|---|
| Detached house standards now vary with total floor area | A small house (the Portal’s example is 100 m²) has a different standard from a large house (250 m²), to reflect energy use and the number of occupants. |
| Two high-rise apartment standards | Separate standards for 6–20 storeys and 21 storeys and higher, to account for shared services. |
| NatHERS whole-of-home calculation incorporated | Aligns BASIX energy calculations with the national requirements in the National Construction Code (NCC), including how occupant numbers are estimated. |
| Energy-efficient lighting assumed | LED-type lighting is assumed in houses and apartments. |
| Grid electricity emissions factor updated | BASIX previously used 1.062 kg CO2-e per kWh. A 10-year average for 2022 to 2031 of 0.67 kg CO2-e per kWh is now adopted, so electric appliances look better than they used to. |
The standards increased for new residential buildings across NSW, except homes in climate zones 9, 10 and 11 (north-eastern NSW) and apartment buildings up to 5 storeys.
How do the Thermal Performance and Energy sections interact?
This is the link most people miss. The Portal’s Thermal Performance guidance says the heating and cooling loads from the Thermal Performance section are combined with the heating and cooling appliances you select in the Energy section to calculate the heating and cooling part of your energy score. Lower loads improve your energy score. In cold or hot climates, the Portal notes, improving thermal performance may be an effective way of getting a Pass in Energy.
Good orientation, insulation, glazing and shading lift the energy score before you spend anything on equipment. Your thermal method matters too. The DIY method estimates loads, while the Simulation method calculates them with NatHERS-accredited software, so outcomes can differ. Our guide to DIY vs NatHERS simulation vs Passive House explains how to choose.
Which hot water system scores best in BASIX?
The Portal’s Hot Water Systems page (last updated 16 November 2026) states that, for the average NSW home, hot water is responsible for the largest share of greenhouse gas emissions. Emissions are calculated from both the efficiency of the system and the emissions intensity of the fuel. Solar and heat pump systems produce the lowest emissions.
| System type BASIX recognises | Key inputs and rules | Emissions outcome (per Portal) |
|---|---|---|
| Solar (flat plate or evacuated tube, gas- or electric-boosted) | Nominate the number of Small-scale Technology Certificates (STCs) for the system | Among the lowest |
| Air source heat pump (all dwellings) | Nominate STCs and check models with those STCs are available at the site’s location (Clean Energy Regulator register) | Among the lowest |
| Ground source heat pump (single dwellings only) | Must also be used for space heating or cooling; if it is the primary hot water system, no other hot water system may be installed | Low |
| Gas instantaneous or storage (boilers in multi-dwelling only) | Nominate the gas star rating | Higher emissions and bills, though usually lower upfront cost |
| Electric instantaneous or storage | New dwellings: usually need solar PV to reach the target. Alterations and additions: solar PV is mandatory to offset it | High |
What is the electric hot water rule for alterations and additions?
The current Portal wording is direct. If you install an electric hot water system as part of an alterations and additions BASIX project, you must include a new or existing on-site solar PV system that at least offsets the electricity used by the new electric hot water system.
- If you add a new PV system, the BASIX Tool calculates the minimum system size required.
- If you rely on an existing PV system, you need to apply for an Alternative Assessment and provide details of that system.
This matters for renovations at or above the $50,000 BASIX threshold. A like-for-like electric storage heater swap that seemed harmless on the drawings can trigger a PV commitment. If you are unsure whether BASIX applies to your renovation, see our guides on BASIX for alterations and additions and when a BASIX certificate is not required. Whether an existing system qualifies is a matter to confirm with the BASIX helpdesk and your certifier.
For the alterations stream more generally, the Portal’s alterations and additions page notes that there are no set percentage reductions for energy or water. Instead the tool encourages efficiency improvements, such as solar, gas, heat pump or wood hot water instead of high-emission electric systems, and at least 40% of new or altered light fixtures fitted with high-efficiency globes.
How does BASIX treat heating and cooling systems?
According to the Portal’s Heating and Cooling page, BASIX assesses the energy used by the main heating and cooling systems for the living room and bedrooms. Secondary heating, such as a fireplace in addition to air conditioning in the living room, is not considered.
Recognised heating options include gas fixed flued heaters (with star rating), gas or heat pump hydronic systems, 1-phase or 3-phase air conditioning (with star rating or EER range), air-conditioning ducting only, electric floor heating, wood heating (single dwellings only), central systems (multi-dwelling only) and no active heating. Cooling options include evaporative cooling, 1-phase or 3-phase air conditioning, ducting only, central cooling (multi-dwelling only) and no active cooling.
Does choosing “no air conditioning” help my score?
Not necessarily. If you select no active system where the Thermal Performance section shows a heating or cooling requirement, the Portal says BASIX assumes a portable or retro-fitted system instead. Leaving it out does not remove the demand, so it is usually better to nominate an efficient system and cut the loads through design.
What does “air-conditioning ducting only” mean?
This option is for homes where, usually for cost reasons, the air-conditioning unit will not be installed by the time the occupation certificate is due. The ducts go in during construction and the unit follows soon after. The trade-off is that BASIX defaults the unit’s efficiency to the lowest value, so your score is calculated conservatively.
What extra paperwork does a ground source heat pump need?
The Portal’s Ground Source Heat Pump page says only closed loop systems are available in BASIX for single detached houses. Ratings must be expressed as EER (cooling) and COP (heating) in units such as W/W or kW/kW. After installation and commissioning, a design engineer or installer must issue a verification certificate listing the installed specifications. It must carry the issuing company’s logo and contact details and be attached with the BASIX certificate in the application for an occupation certificate. Open loop or multi-dwelling systems need a conversation with the BASIX helpdesk about an alternative assessment.
Do ceiling fans count?
Ceiling fans are entered in the Thermal Performance section, not the Energy section. The Portal’s ceiling fans page says at least one ceiling fan must be installed in a daytime habitable space if the dwelling is in NCC climate zone 5, with the number and diameter set by room size (drawn from NCC 2022 Table 13.5.2). In other climate zones fans are optional but can reduce the cooling load. Check your climate zone with your BASIX assessor.
What ventilation choices does BASIX recognise?
You need to provide ventilation to the bathroom, kitchen and laundry. For single dwellings, the Portal’s Single Dwelling Ventilation page lists three system types and five operation controls:
| System type | Operation controls available |
|---|---|
| No mechanical ventilation (natural ventilation) | Interlocked to light · interlocked to light with timer off · continuous (24 hours) · manual on/off · manual on/timed off |
| Individual fan, not ducted | |
| Individual fan, ducted to façade or roof |
All systems must be designed to the NCC, which in turn calls up AS 1668.1 and AS 1668.2 for mechanical ventilation. The Portal notes a controlled fan (manual or interlocked to the light) uses less energy than a continuous one, and recommends an external outlet, short duct runs and back-draft dampers. If you use the Passive House method for thermal performance, mechanical ventilation with heat recovery (MVHR) is mandatory. For the history of roof-space exhaust, see our article on BASIX ventilation changes.
How is lighting assessed?
Lighting has two parts.
- Natural lighting. The Natural Lighting page says BASIX asks whether the kitchen has a window or skylight and how many separate bathrooms or toilets are naturally lit. The window must be in the room’s perimeter wall, or the skylight in the room’s roof. A toilet inside a bathroom cannot be counted twice.
- Artificial lighting. The Artificial Lighting page says a minimum of 80% of light fittings must be compact fluorescent, fluorescent or LED. BASIX assumes an average of 4 W/m² for artificial lighting, and the Portal notes LEDs can keep most rooms below 1 W/m². “Dedicated” fittings that only accept fluorescent or LED lamps lock in efficiency for the life of the building.
How does solar PV affect the BASIX energy score?
The Portal’s Photovoltaics page says BASIX assesses PV on the total rated output of all panels in kilowatts. You can enter one or two panel groups (for different orientations or slopes), each with rated output, roof slope and orientation.
The crucial point: BASIX offsets emissions from the home’s electricity use only. Emissions from gas appliances are not offset by PV. The Portal concludes that, to achieve the highest BASIX energy score, the home needs to be fully electric. The Portal also advises making the home and appliances efficient before sizing PV, avoiding shade, and checking whether neighbours could later build tall enough to overshadow the panels.
For more on PV and batteries, read BASIX solar PV and battery storage and our overview of all-electric homes in NSW.
What about pools, spas and other appliances?
If your project includes a pool or spa, the Portal’s Pools and Spas page says BASIX assesses volume, indoor or outdoor location, cover, shading, heating system, and pump system, rating and timer. Recognised heating options are none, solar, gas, electric heat pump, electric resistance and (multi-dwelling only) cogeneration heat. The Portal identifies solar as the most efficient way to heat a pool or spa, and to count as shaded at least 80% of the pool must be covered by a compliant shading device. Our BASIX pools and spas guide covers when a pool triggers BASIX.
Under other energy uses, the Portal’s design principles mention induction (or gas) cooking, ventilation space around the fridge, clothes drying lines, and energy-efficient appliances (the Portal points to the Australian Government’s Energy Rating website for star ratings).
What if my technology is not in the BASIX Tool?
Technologies the tool does not define, such as geothermal heating, can be put to the Department through a new technology application. Among other criteria, the technology must save more than 1% of an average dwelling’s greenhouse gas emissions (85 kg CO2-e per year) or potable water use and have at least one year of demonstrated savings. Approval is at the Department’s discretion.
How do you complete the Energy section step by step?
- Confirm BASIX applies and which stream you are in: new single dwelling, multi-dwelling, or alterations and additions ($50,000 or more).
- Look up your energy standard using the Department’s calculator for your postcode and building type.
- Settle thermal performance first. Choose DIY, Simulation (NatHERS) or Passive House, and reduce heating and cooling loads through design.
- Choose the hot water system and get the STC count for solar or heat pump units.
- Nominate heating and cooling at the star rating or EER you will actually buy.
- Set ventilation types and controls for bathrooms, kitchen and laundry.
- Enter lighting: natural light to kitchen and wet areas, and the LED or fluorescent share of fittings.
- Add pool, spa and appliance details.
- Add solar PV (rated output, slope, orientation for up to two panel groups) if needed, and calculate.
- Check the score against the target, adjust, generate the certificate and show every commitment on the plans.
Once issued, a certificate generally has to be lodged within three months, and design changes may need a revised certificate. See BASIX certificate validity and Planning Portal certificate validation.
What goes wrong most often in the Energy section?
- Unchecked equipment. A heat pump with the nominated STCs may not be available at your location.
- Builder substitutions. Swapping a heat pump for electric storage, or downgrading an air conditioner, can breach the certificate. Confirm with your certifier whether a revised certificate or modification is needed before ordering.
- Forgetting the occupation certificate. The certifier checks that BASIX commitments are installed. Ground source systems also need the verification certificate. Our BASIX completion receipt guide explains that final step.
- Treating PV as a cure-all. PV does not offset gas appliances, so a home with gas hot water and gas heating may need far more panels than expected, or a different equipment mix.
- Ignoring water efficiency. The Portal’s Water section notes that efficient showerheads and taps reduce hot water demand and improve your Energy score too. See our BASIX water efficiency guide.
Does the NCC still apply on top of BASIX?
Yes, in part. The Department’s NCC and BASIX guidance material explains that NSW Part H6 of NCC 2022 contains energy efficiency provisions (covering building fabric, building sealing and services) that apply to new Class 1 buildings in addition to BASIX. Which NCC edition applies is linked to the BASIX certificate version: a certificate issued under Version 4.0 or later brings in the NCC 2022 NSW provisions, while Version 3.0 or earlier links to NCC 2019 Amendment 1. The version number is printed at the bottom of each certificate page. Confirm the applicable provisions with your certifier.
Frequently asked questions
Is hot water really the biggest factor in the BASIX energy score?
For the average NSW home, the Planning Portal says hot water is responsible for the largest share of greenhouse gas emissions, so it is usually the most powerful lever. Solar and heat pump systems produce the lowest emissions.
Can I pass BASIX Energy with gas appliances?
Gas hot water and heating are still recognised options. However, solar PV does not offset gas emissions, and the Portal states that a fully electric home is needed for the highest energy score. Whether a gas design passes depends on your target and other choices.
Can I install electric hot water in a renovation?
In an alterations and additions BASIX project, yes, but only with a new or existing on-site solar PV system that at least offsets the electricity it uses. An existing system requires an Alternative Assessment.
Do I have to list every light fitting?
No. BASIX assumes an average of 4 W/m² for artificial lighting, and asks whether at least 80% of fittings are fluorescent or LED, plus which rooms get direct natural light.
What if the air conditioner will not be installed before the occupation certificate?
You can select “air-conditioning ducting only”. BASIX will then assume the lowest efficiency value for the unit.
Where do I find my energy target?
Use the Department’s Energy standards and thermal loads calculator, linked from the Planning Portal’s Energy section page. Targets vary by climate zone, building type and, for detached houses, total floor area.
Need help getting your BASIX Energy section right?
giantA prepares BASIX certificates and NatHERS-based thermal assessments alongside DA and CDC drawings, so the equipment commitments match the plans from the start. See our BASIX and NatHERS services or BASIX assessment in Sydney, or contact us for a quote.
This article summarises NSW Planning Portal guidance as at 19 November 2026. It is general information, not advice for your site. Requirements can change, and interpretive points should be confirmed with your certifier, the BASIX helpdesk or the consent authority.
Sources
- NSW Planning Portal – BASIX Energy section (updated 20/10/2026)
- NSW Planning Portal – Hot Water Systems (updated 16/11/2026)
- NSW Planning Portal – Heating and Cooling
- NSW Planning Portal – Single Dwelling Ventilation
- NSW Planning Portal – Photovoltaics
- NSW Planning Portal – Assessment against requirements
- NSW Planning Portal – Increase to BASIX Standards
- NSW Planning Portal – Thermal Performance section
- State Environmental Planning Policy (Sustainable Buildings) 2022